1ATTENTION INSTALLER:THIS DOCUMENT IS PURCHASER’S PROPERTY AND IS TO REMAIN WITH THE HEAT PUMP OWNERModels:T65T115T135Pool and SpaHeat PumpOwner’s Man
10Dimensional Information - TropiCalModel T135BDATA PLATEINFORMATIONBACONTROL BOXACCESS PANELCOMPRESSORACCESS PANEL1. ALL DIMENSIONS IN INCHES2. MIN.
11Refrigerant Circuit Performance ChartsUse of Charts- Information for the Technician:The charts are intended for use by trained and qualified air-con
12Refrigerant Circuit Performance ChartsFor use with Troubleshooting Refrigerant Circuit Problems guide, following charts.
13NOTE: These guidelines are for use only by experienced, EPA certified, HVAC technicians, andwere developed specifically for use with AquaCal heat p
14TXV Stuck Open:• Head pressure will be slightly to moderately low;• Suction pressure will be slightly high to very high;• Amperage (not a reliable
15Typical Installation ClearancesCode Required Clearances:In addition to the previously stated clearance requirements, follow all applicable local, st
16Plumbing RequirementsOverview:When planning plumbing system layout, reference the plumbing schematics following this section as a guide to thesequen
17Plumbing Schematics
18Water IN & OUT ConnectionsFor proper operation and maximum efficiency, piping coming from the pump and filter MUST be connected to the"IN&q
19Code Requirements:u The electrical installation must conform to the most current version of the NationalElectrical Code, NFPA No. 70, and all appli
2NOTES________________________________________________________________________________________________________________________________________________
201. POOL TEMPERATURE CONTROL - Set this knob for desired pool water temperature2. POOL/OFF/SPA -Toggles between pool temperature/off/spa temperature3
211. Lower Thermostat Settings-Set P/O/S Toggle Switch to OFF:u Turn both thermostat knobs counterclockwise to lowest settings.u Position the POOL/OFF
224. Ensure Uninterrupted Pump Operation During Initial Warm-Up:u Permit your pool or spa circulation pump to run continuously until the desired water
23Pool and Spa Combination HeatingEverything stated for heating a pool applies for heating a spa; only the volume of water being heated is different.T
24Volume of Pool (Length X Width X Average Depth) = _________ Pool Cubic FeetX Gallons per cubic ft.(7.5) = _________ Pool GallonageX P
25Planned Maintenance ProgramJust as you would have yearly service performed on your air conditioning system, regular inspection &maintenance of y
26u Control Irrigation: In regions were wells are used for irrigation, water quality is sometimes less thanpoor, and water spray can damage heater co
27During the Swim Seasonu During the swim season, even if the pool or spa is not in use, allow water to flow through the heater.u This eliminates the
28Winterizing Procedure:1. Disconnect all electrical power to the heater; turn OFF circulating pump.2. At the two (2) water connection unions, disconn
29Common Troubleshooting IssuesHeat Pump Not RunningIs the power light lit?If not, ensure the main breaker (located at the power supply panel) and the
3TABLE OF CONTENTSWELCOME TO THE TEAM ------------------------------------------------------------------ 4IMPORTANT FEATURES OF YOUR NEW HEAT PUMP ---
30STARTIs the thermostat turned UP, and the toggle or rocker switch selecting either theSPA or POOL thermostat ?STARTIs the thermostat turned UP, an
31STARTIs the air being dischargedout of the top of the heater 9-12degrees cooler than theoutside air?STARTIs the air being dischargedout of the top o
32STARTIs the flow light onand the unitheating?STARTIs the flow light onand the unitheating?Call AquaCal forAssistance: 800-786-7751Call AquaCal forAs
33Heater Short CyclingAnalog Controls - 12/22/03 STARTIf the heater is turning on andoff every 5 minutes:Make sure all water valves arein the correct
34Effective 09/01/2003To order replacement parts, contact AquaCal Customer Support: (800) 786-7751REPLACEMENT PARTS VOLTAGE : 1/60/208-230 VOLTAGE :
35What We Need to Know When You Call UsIf you should need to call AquaCal for service, please have the following information ready:Model: ____________
362737 24th St. NorthSt. Petersburg, FL 337131-800-786-7751
4WelcomeeamT“You can rest assuredthat your new heatpump is of the highestquality and efficiency,and is designed andbuilt to provide years oftrouble-fr
5ThermoLink HeatExchanger:The heart of your heatpump is the patentedThermoLink heat ex-changer. The primarycause of prematureheat pump demise isthe f
6Used and maintained properly, your heat pump will provide year-upon-year of safe and economical service.However, as with any mechanical or electrical
7Refrigerant Circuit Service Only byQualified, EPA Certified TechnicianHeater NOT Repairable by OwnerWARNING !Failure to heed the following may result
8This brief information is provided as an aide to installers, service personnel, and owners. The intent of thissection is to provide rapid access to (
9PHYSICAL CHARACTERISTICS& PERFORMANCE1. ALL DIMENSIONS IN INCHES2. MIN. CLEARANCE 24" FROM AIR COILBDATA PLATEINFORMATIONBREAR VIEWJKHPO
Commentaires sur ces manuels